German term
Aufnahmedosis
German to English
Medical
Medical: Cardiology
In a coronary angiogram report I have both Durchleuchtungsdosis and Aufnahmedosis. Both with the unit Gycm2
I have got myself in a muddle with all of the various radiation measures, so I was hoping for some clarification between the two terms.
And do either of these represent DAP, or is that yet another measure?
I have got myself in a muddle with all of the various radiation measures, so I was hoping for some clarification between the two terms.
And do either of these represent DAP, or is that yet another measure?
Proposed translations
(English)
3 +1 | (cine) acquisition dose | Anne Schulz |
4 | radiation dose | Lirka |
3 | exposure dose | Brent Sørensen |
3 | Absorbed dose | Stuart and Aida Nelson |
Change log
Dec 2, 2020 15:46: Anne Schulz Created KOG entry
Proposed translations
+1
5 hrs
Selected
(cine) acquisition dose
Both fluoroscopy and specific cine acquisitions are used for coronary angiography procedures. For radiation dose, a distinction can be made between the dose caused by fluoroscopy monitoring and the dose due to cine acquisitions. In your context, "Aufnahmedosis" may therefore refer to the cine acquisition component (although it is not a specific term for that).
"Data were acquired for each fluoroscopic and acquisition dose curve within each vendor's default abdomen or body imaging protocol."
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690202/
"Table TID 10004. Accumulated Fluoroscopy and Acquisition Projection X-Ray Dose"
http://dicom.nema.org/medical/dicom/current/output/chtml/par...
--------------------------------------------------
Note added at 1 day 4 hrs (2020-11-27 15:38:12 GMT)
--------------------------------------------------
Let me add that "Aufnahmedosis" is not a defined technical term in this context (as confirmed by the variability in the proposed answers). IMO, there is nothing wrong to pass the buck back to the author(s) with a translator's note.
"Data were acquired for each fluoroscopic and acquisition dose curve within each vendor's default abdomen or body imaging protocol."
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690202/
"Table TID 10004. Accumulated Fluoroscopy and Acquisition Projection X-Ray Dose"
http://dicom.nema.org/medical/dicom/current/output/chtml/par...
--------------------------------------------------
Note added at 1 day 4 hrs (2020-11-27 15:38:12 GMT)
--------------------------------------------------
Let me add that "Aufnahmedosis" is not a defined technical term in this context (as confirmed by the variability in the proposed answers). IMO, there is nothing wrong to pass the buck back to the author(s) with a translator's note.
4 KudoZ points awarded for this answer.
Comment: "Thanks. This makes most sense in my context. I did subsequently realise that there was a third value "Gesamtdosis" that was the sum of the "Aufnahmedosis" and "Durchleuchtungsdosis", so that would fit with your interpretation."
3 hrs
exposure dose
Bei herkömmlicher Aufnahmedosis muß in digitalen Radiographien eine geringere Erkennbarkeit venöser Katheter in Kauf genommen werden
Detection of low contrast catheters was found to be significantly decreased in storage phosphor radiographs obtained with standard exposure dose.
https://www.thieme-connect.com/products/ejournals/abstract/1...
--------------------------------------------------
Note added at 3 hrs (2020-11-26 14:25:49 GMT)
--------------------------------------------------
Durchleuchtungsdosis = fluoroscopic dose
https://books.google.de/books?id=IkX0BQAAQBAJ&pg=PA88&lpg=PA...
4 hrs
radiation dose
As I understand it, Aufnahmedosis (radiation dose) is a general term, a dose of radiation delivered during ANY radiographic examination (X-ray, CT, mammography, fluoroscopy).
Durchleuchtung (fluoroscopy), and its radiation dose, is a special type of radiographic examination where the radiation dose tends to be higher.
So, your terms are: radiation dose and fluoroscopy radiation dose. They refer to the same thing, i.e. radiation dose, but one is general and the other one is associated with a specific type of exam.
It's somewhat like saying: juice and orange juice.
HTH
Durchleuchtung (fluoroscopy), and its radiation dose, is a special type of radiographic examination where the radiation dose tends to be higher.
So, your terms are: radiation dose and fluoroscopy radiation dose. They refer to the same thing, i.e. radiation dose, but one is general and the other one is associated with a specific type of exam.
It's somewhat like saying: juice and orange juice.
HTH
8 hrs
Absorbed dose
Absorbed dose is the amount of energy deposited by radiation in a mass. The mass can be anything: water, rock, air, people, etc. Absorbed dose is expressed in milligrays (mGy).
Please also note the equivalent dose and effective dose.
http://icrpaedia.org/Absorbed,_Equivalent,_and_Effective_Dos...
An Introduction to Fluoroscopy Safety
Quantities and Units
Absorbed dose
The absorbed dose is the amount of radiation energy absorbed by tissue per mass of tissue. Skin typically receives the highest absorbed dose.
Kerma Area Product
The kerma area product (KAP) is a measure of dose integrated across the entire exposed field. KAP is sometimes called dose area product (DAP). It is usually expressed in mGycm2.
https://www.mpcphysics.com/documents/IntroductiontoFluorosco...
Durchleuchtung:
• Dosisflächenprodukt (DFP) – Gy×cm²
Das Dosisflächenprodukt entspricht der gesamten, bei einer Untersuchung das
Röhren-Austrittsfenster passierenden "Strahlenmenge". Das Dosisflächenprodukt wird mittels einer Ionisationskammer am Strahlenaustrittsfenster ermittelt. Es entspricht dem Produkt aus Dosis und Nutzstrahlenfläche.
Radiographie:
• Oberflächendosis
(ESD Entrance Surface Dose) – mGy
Die Oberflächendosis ist die Energiedosis (inkl. Rückstreuung) in einem bestimmten Abstand von der Strahlenquelle auf der Oberfläche des bestrahlten Körpers. Die Werte können mittels an der Hautoberfläche angeordneten Ionisationskammer gemessen werden. Dieses Verfahren wird in der Personendosimetrie mittels dem Thermolumineszenzdosimeter (TLD) angewendet.
• Organdosis – mSv
Die Organdosis ist die absorbierte Energiedosis in einem bestimmten Organ,
welche durch ionisierende Strahlung aufgenommen wurde. Sie ist relevant für die Auswirkung auf das betroffene Gebiet, das betrifft insbesondere die
strahlensensiblen Organe.
https://www.svmtra.ch/files/Dokumente/Verband/Fachstellen/St...
--------------------------------------------------
Note added at 10 hrs (2020-11-26 21:35:04 GMT)
--------------------------------------------------
The following link clearly shows that absorbed dose is used within cardiac angiography (angiogram):
Radiation Dose to Patients From Cardiac Diagnostic Imaging
While often easy to measure, exposure and air kerma specifically measure ionization in air, not tissue, and thus do not directly quantify radiation’s effect on humans. Absorbed dose is the mean energy imparted to the matter in a volume by ionizing radiation, divided by the mass of the matter in the volume. The SI unit of absorbed dose, introduced at the 15th CGPM in 1975, is the gray (Gy), which is a special name for joule per kilogram.
https://www.ahajournals.org/doi/10.1161/circulationaha.107.6...
Reference comments
8 hrs
Reference:
Dosisflächenprodukt - Dose Area Product (DAP)
Das Dosisflächenprodukt (DFP) ist definiert als das Flächenintegral der Luftkerma über eine Schnittebene durch das Bestrahlungsfeld. Es entspricht praktisch dem Produkt aus der bestrahlten Fläche (in cm²) und der dort wirksamen Dosis (in Gray).
Synonym wird auch der Begriff Dose Area Product (DAP) und wurde früher der Begriff Flächendosisprodukt verwandt.
https://edoc.ub.uni-muenchen.de/16449/1/Rettinger_Tobias.pdf
The diagrams show that DAP with the unit Gycm2 is used for both Durchleuchtungsdosis and Aufnahmedosis.
Synonym wird auch der Begriff Dose Area Product (DAP) und wurde früher der Begriff Flächendosisprodukt verwandt.
https://edoc.ub.uni-muenchen.de/16449/1/Rettinger_Tobias.pdf
The diagrams show that DAP with the unit Gycm2 is used for both Durchleuchtungsdosis and Aufnahmedosis.
Peer comments on this reference comment:
agree |
Anne Schulz
: Das wäre schon mal geklärt :-)
1 hr
|
Danke Anne :)
|
Something went wrong...